Book a Call

Edit Template

Products

Affordable & Flexible Electrochemical Systems

cs 150m

Potentiostat/ Galvanostat

cs 300m

Potentiostat/ Galvanostat

CS 310x

Multi Channel Potentiostat
(8 Channel)

CS 350M

CS Series Potentiostat

CS2350M

Bipotentiostat
(2- Channel) with EIS

Features

Accessories

CS 900

Saturated Calomel Electrode

CS 900

1. Please remove the cap before first time use.
2. If there is air bubbles trapped in the tube, please swing the electrode body to remove air bubbles.
3. There is a little KCl crystalloid remained in the solution to make sure the solution is saturated.
4. Please take off the side cap of the electrode, and refill solution from the side solution filling port. 
5. After use, please dip the electrode into saturated KCl solution.

CS 901

Ag-Agcl Reference Electrode

CS 901

 It consists of a Teflon cap with a AgCl coated Ag wire, a glass tubing, and a porous Teflon tip sealed into the glass tubing.
 Porous Teflon tip has the following advantages: slow solution leak and more durability due to its perfect chemical inertness. However, you should still take good care of the electrode. 

CS 902

Alkaline Mercurous Oxide Reference Electrode

CS 902

1.  Take off the rubber cover at the part of the electrode interface.
2. There shouldn’t be air bubbles in the solution in salt bridge. Remove air bubbles of the tube before first use.  
3. During measurement, the level of solution in salt bridge should be higher than the solution of the sample.
4. Store the electrode in alkaline solution.
5. Regularly replace with solution in the salt bridge and clean the internal wall of the electrode.

CS 903

Mercurous Sulphate Reference Electrode

CS 903

1. Please remove cap before the first use.
2. If there is air bubbles trapped in the chamber, please swing the electrode body to remove air bubbles.
3. Please fill with saturated K2SO4 solution if the solution inside the electrode is at low level.
4. After use, please dip the electrode into saturated K2SO4 solution. 
 

CS 910

Platinum Conductivity Electrode

CS 910

With relatively big size, platinum conductivity counter electrode(CS910) is usually used in the CS930 4-neck electrolytic cell.
In CS930 Cell, working electrode is usually CS921 Metal electrode or CS946 specimen holder.
Reference electrode is usually CS900 Saturated calomel electrode.
This set is usually used for corrosion field.

CS 912

Platinum Wire Counter Electrode

CS 912

Specifications

Platinum purity: 99.95%
Platinum wire: φ0.5*37mm
Total length: 82mm
PTFE part: length 25mm, Outer diameter: 6mm
Copper part: length 20mm, diameter 2mm
 

CS 920

Glassy Carbon Working Electrode

CS 920

Specifications
GC disk diameter:3mm
Total length: 80mm
PTFE part: length 60mm, Outer diameter 6mm
Copper part: length 20mm, diameter 2mm

CS 921

Metal Electrode

CS 921

It is usually used in CS930 4-neck cell. 

Working area: 0.5cm2
Material: Optional
Carbon steel(Q235),Stainless steel(304, 316L, SS316 L), Pure Copper, Pure Magnesium, AZ31 Magnesium alloy, 13Cr Stainless Steel, Duplex 22Cr Stainless Steel, X65 Carbon steel, Pure Aluminum, Pure Iron, Cu70-Ni30 Alloy, Cu90-Ni10 Alloy,  Aluminum 6082 Alloy, Carbon Steel T-95, Carbon Steel X100 
Inconel 600

CS 922

Platinum Working Electrode

CS 922

Specifications
Platinum purity: 99.99%
Platinum disk diameter: 2mm/3mm
Total length: 80mm
PTFE part: length 60mm, Outer diameter 6mm
Copper part: length 20mm, diameter 2mm
 

CS 923

Gold Working Electrode

CS 923

Brass Rod DIA: 2mm

Teflon DIA: 6mm

Gold DIA: 2mm

Teflon Length: 60mm

Brass Rod Length: 20mm

CS 930

4-neck Glass Electolyte Cell

CS 930

The matching electrodes with this cells are usually: 
Reference electrode: CS900 Saturated Calomel electrode
Counter Electrode: CS910 Pt conductivity electrode or CS911 Pt plate electrode
Working electrode: CS921 metal working electrode or CS946 Specimen holder with your sample assembled
 

CS 935

Sealed Electrolyte cell

CS 935

Standard cell (None-sealed,CS935) 
Volume: 150mL/200mL/250mL
Electrodes are not included
The holes on the Teflon lid are tailored according to requirement. You just tell us which electrodes will be inserted.

CS 936

Flat Corrosion Cell

CS 936

CS936 Jacketed & None-Jacketed Flat corrosion cell
Effective working area is 1cm2
include:
Ag/AgCl reference electrode*1
Built-in counter electrode: Pt mesh*1 (20*20mm)

CS 942

Electrode Polishing Kit

CS 942

Electrode polishing kit (CS942) includes the following:
0.05µm Alpha alumina powder 20g  
0.3µm powder 20g  
1µm powder 20g  
Nylon polishing pad (Ø200mm) *1 
Microcloth polishing pad (Ø200mm)*1
Carbimet disks
 (1200-4000 grit, Ø200mm)*1
-Glass plate*2
 

CS 945

Electrode Clamp

CS 945

Suitable for plate specimen with thickness better less than 1mm. 
After customization, however, it can also clamp thicker plate specimen suc as 2.2mm FTO/ITO Glass.
 

Contact Info

Need Consultation?

Contact Us for Your Requirements

Affordable & Flexible Electrochemical Systems

Contact Us

© 2024 Corrtest India | Developed & Designed by Studio Digital